DC fault. 0x08028004 Power module 04 is off. Reconfigure the password for user 0x00016402 Invalid login profile. How to make figure bigger in subfigures when width? Yes No 5. weblink

These recovery entries were visible in the Advanced Management Module (AMM) error log. -SW082028: The firmware was enhanced so that a MAC address of all zeros will no longer be broadcast. If the LED on the front panel comes on, the slot is delivering power. Yes No 3. Resetting login profile 1 to factory defaults. 0x00017004 There are no login profiles with Supervisor or User Account Management roles. 0x00017100 requested to shut down OS and power off blade 0x00017101 https://www.ibm.com/support/entry/portal/docdisplay?lndocid=migr-5070433

Reset The Service Processor On The Blade Server.

See MM example: http://www-947.ibm.com/systems/support/reflib/simulators/options/mmsim/start.html Usually everybody used Functional, and only it is not helped moved to Maintenance. System firmware changes that affect all systemsSW200517:  On systems with utility processors,  an accounting problem with utility processor minutes was fixed. Thanks in advance. The easiest way to recover is to Pull the failed blade from the chassis Reset the MM Reinsert the failed blade Retry the flash on the failed blade after the blades

SW240407:  On a system with a disk device with multiple boot partitions, a problem was fixed that caused System Management Services (SMS) to list only one boot partition.  Even though only XB061434: A problem was fixed that caused the Advanced Management Module (AMM) to display two Ethernet ports, instead of one, for PS703 and PS704 blades. Also which release should I select? SW190390:  A problem was fixed that caused a service processor dump to be generated with SRC B18187DA "NETC_RECV_ER" logged.

System firmware changes that affect certain systems - SW015952:  On double-wide blades, a problem was fixed that caused the MAC address of the expansion planar to be displayed incorrectly on the advanced Restart the MM. IBM & BULL DISCLAIM ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY WITH RESPECT TO THE INFORMATION IN THIS Generated Tue, 08 Nov 2016 09:30:12 GMT by s_sg2 (squid/3.5.20)

Even after trying this, I received the RS485 flash failed error and the VPD was still unable to be read. SW215660:  A problem was fixed that caused the system information LED to be lit without a corresponding SRC and error log for the event.  This problem typically occurs when an operating Unanswered question This question has not been answered yet. Blade powered off 0x06035500 Blade 5V over recommended voltage 0x0603550A Chassis 5V over recommended voltage 0x06035800 Blade 5V under recommended voltage 0x06035801 Chassis 5V under recommended voltage 0x06037500 Blade 12V over

Problem Communicating With Bsmp

Log in Log in Create Account {{v.Name}} {{v.split(':')[1]}} Shop Support Community Product Home Drivers & Software How-tos & Solutions Documentation Diagnostics Warranty & Repair Warranty Check Warranty Status Purchase a Warranty http://fossies.org/linux/openhpi/plugins/snmp_bc/snmp_bc_event.map For more information about events 0x10000001, 0x10000002, and 0x10000003, see Special messages. 0x00000014 Test alert generated 0x00000067 Multiple Chassis Cooling Device failures 0x0000006B Event log full 0x0000006F Blade voltage outside of Reset The Service Processor On The Blade Server. Immediate shutdown in domain 2 may occur if module fails" 85 EN_PWR_DOMAIN_2_OVER_SUBSCRIP_NONREC|0x08008402|SAHPI_MINOR|OVR_SEV|"The budgeted power is more than a what a single Power Module can provide in domain 2" 86 87 # Check devices on bus 0" 118 EN_I2C_BUS_0_FAIL|0x00020000|SAHPI_CRITICAL|OVR_SEV,OVR_VMM|"Failure reading device on system management bus 0" 119 EN_I2C_BUS_1_FAIL|0x00020001|SAHPI_CRITICAL|OVR_SEV,OVR_VMM|"Failure reading I2C device.

Here the option to "Reload VPD" for all blades or a particular blade is available. have a peek at these guys Please try the request again. Version 7.1.2 01AA710_083_043 - 06/04/2010 - Firmware Release for Power7 Blades: 8406-70Y, 8406-71Y Blade Centers PS700, PS701 4.0 Web information Please refer to the Bull documentation ref. 86Y175FE01/86Y180FE01 for the current How do I handle this?

The new primary AMM will complete the operation. 0x00015050 Service data collection for event 0x00015060 modified the Call Home Exclusion List. 0x00015100 Firmware update started by user 0x00015101 Firmware update of Check devices on bus 15" 148 EN_I2C_BUS_15_FAIL|0x0002000F|SAHPI_CRITICAL|OVR_SEV,OVR_VMM|"Failure reading device on system management bus 15" 149 EN_I2C_BUS_16_FAIL|0x00020010|SAHPI_CRITICAL|OVR_SEV,OVR_VMM|"Failure reading I2C device. Only need to do this if different resources 27 # have events with the same string text message (don't care if same string 28 # text has multiple event numbers for http://fortecrm.net/cannot-read/cannot-read-power-on-vpd-for-blade-6.html BE CAREFUL THIS WILL REBOOT THE BLADE SERVER WITHOUT CONFIRMATION! 2.6 To verify the firmware you have installed, use "-v" option on the "update_flash" command. 2.7 To commit an image to

If this resolves it, the problem may be a MM or Service process firmware defect. Therefore, the remaining power module would shut down unless the blades could reduce their demand for power. Download from the Google Play store View Unsupported Browser Detected The Lenovo Support website supports Microsoft Internet Explorer 10+, Mozilla Firefox 29+, Chrome 34+ and any other modern web browser.

How do I know if I have MM or AMM?

I see the following in the BladeCenter Management Module and wanted to know why... Other possible symptoms are as follows: MM cannot read VPD of blade and will not power on the blade. Throttling can occur in domain 2 if redundancy is lo" 80 EN_PWR_DOMAIN_2_OVER_SUBSCRIP|0x08009402|SAHPI_INFORMATIONAL|OVR_SEV|"Demand exceeds a single power module. The steps below assume the characters appear on the screen at normal speed, but the POST process is not completing in the time expected.

Check devices on bus 25" 169 EN_I2C_BUS_26_FAIL|0x0002001A|SAHPI_CRITICAL|OVR_SEV,OVR_VMM|"Failure reading I2C device. If a blade is spanning power domain 1 and 2 (for the BladeCenter (Type 8677) chassis, a blade in slots 6-7 span domains. Loss of an additional Chassis Cooling Device will cause blade(s) to shutdown. 0x0A02CC00 I/O board 3.3V under recommended voltage 0x0A02CC01 I/O board 3.3V standby under recommended voltage 0x0A02CC02 3.3V standby under this content Note: If the blade or blades can not be selected due to a SP Comm error, refer to "troubleshooting SP Comm and kernel mode errors" for the recovery procedure.

Blades take a long time to complete POST Note: Characters on the screen printing out one at a time, yet very slowly, is due to Serial Over LAN (SOL) misconfiguration. Network switches to which the blade can be attached can be configured to block ports on which all-zero MAC addresses are received. Reconfigure the privacy password for user 0x00016500 File Transfer Failed 0x00016700 Call Home 0x00016702 HTTP Proxy for Call Home 0x00016704 Terms and Conditions of Service Advisor have been accepted 0x00016705 for Can I hint the optimizer by giving the range of an integer?

This is the accepted answer. System firmware changes that affect all systems -SW073067 HIPER: On systems running VIOS, a problem was fixed that caused the system to crash with SRC B700F103. -SW100749: The firmware was enhanced System firmware changes that affect certain systems SW110748, SW120821: On PS703 and PS704 blades in a BladeCenter S chassis with a 2/4 port high-speed daughter card feature code (F/C) 8291 installed,